Quality Control of Lung SBRT: From 4D Simulation to 4D Verification
Track : Panel
Program Code: P11
Date: Tuesday, October 30, 2012
Time: 4:45 PM to 6:15 PM  EST
Duration: 90 Minutes
Location: 210ABC
SPEAKER(S):
Fang-Fang Yin
Jeffrey Bradley, Md
Jing Cai, PhD
Krishni Wijesooriya, PhD
Description
Stringent quality control is critical to the success of lung SBRT. However, uncertainties exist in each step of the lung SBRT procedure. Characterization of organ motion using 4DCT may not present true tumor motion excursion due to its low temporal resolution and patients' breathing irregularity. In treatment planning, tumor ITV could be significantly under-/over-estimated by 4DCT. Different delivery techniques such as 3D-conformal, IMRT/VMAT, may introduce different degrees of uncertainties. The relative pros/cons of each motion management technique are usually not patient-specifically quantified, leading to uncertainty in finding the optimal technique for the patient. Other uncertainties include the choosing of planning CT, the determination of PTV and gating window, etc. At patient positioning, image guidance is prone to uncertainties due to technical limitations: CBCT may not present true ITV due to patient's irregular breathing. Rotational errors may not be fully corrected without six degree-of-freedom couch. At dose delivery, correlation between external motion and tumor motion is uncertain for respiratory-gated treatment. Tumor motion and size during treatment may be different from those measured at simulation, and may vary between fractions. For physics QAs, uncertainties in dose measurement devices and delivery devices could be substantial with inhomogeneity tissues. Quality control of lung SBRT requires accurate quantification of target motion by using the proper 4D-imaging technique and parameters based on patient's conditions, quantitative evaluation of different planning techniques, QA of treatment plan using 4D dosimeter and 4D phantom simulations, optimal patient positioning and motion monitoring during treatments. At the conclusion of this activity, the learner will be able to do the following: 1. Demonstrate an evidence-based systematic review of uncertainties during lung SBRT. 2. Discuss the root causes of the uncertainties and corresponding quality control strategies. 3. Explain data-driven practical and effective solutions to minimize the uncertainties.


Audio Synchronized to PowerPoint
(Code: P11)
Non-Attendee/Member-in-Training:
Non-Attendee/Member:
Attendee:Free